Image checks

Get an alarm when a camera's lens is covered or blinded, its view is moved, or its image loses focus, and choose the sensitivity, the faults to report and when each camera is checked.

Content updated Applies to version 3.0.1 Print view kalytera-cloud image-checks tampering camera-health alarms schedules
Contents

Image checks raise an alarm when a camera's picture is tampered with or degrades: the lens is covered or blinded, the camera is moved, or the image loses focus. They are an add-on for your portal. Turning them on needs permission to change the camera. The checks learn each camera's normal view by themselves, so there are no reference pictures to manage.

Turn image checks on

  1. Open the camera under Cameras, stay on its Overview and select Edit details.
  2. Turn on Image checks.
  3. Choose the Sensitivity, the faults to report and when to Check, as described below.
  4. Select Save details.

A camera is checked only while it is enabled and its video reaches Kalytera Cloud. The checks learn its day, night and infrared views over time.

Sensitivity

LevelReacts to
LowOnly large problems that last about two minutes.
NormalClear problems that last about half a minute. This is the default.
HighSmaller problems after about 15 seconds.

Choose what raises an alarm

Under Raise an alarm when, all three faults are ticked. Untick any you do not want reported:

  • The lens is covered, or the image goes dark or washed out
  • The camera is moved or its view changes (leave off for PTZ cameras)
  • The image loses focus

For a scene left unlit at night, tick Don't raise an alarm when the image is only dark. A lens covered so that the image goes black is then not reported either; covers that let light through still are.

Check on a schedule

Check is Always by default. To check the camera only at set times, choose the option that reads During followed by the name of one of your schedules. Outside its periods, and while the schedule's Enabled box is cleared, the camera is not checked. A problem that is already open stays open.

Build schedules under Cameras > Schedules and holidays. Schedules and holidays is available with image checks or cloud recording; image checks do not require recording. See Schedules and holidays.

Status on the camera's overview

The Image checks card on the camera's Overview shows one status:

  • On, with a detail such as No problem found., Paused outside its schedule. or Not checked while the camera has no video.
  • On with Learning the camera's view. until the checks have learned the first view. Later views are learned without a message.
  • Problem found, with what was found and since when. It returns to On once the image has looked normal for about half a minute.
  • Off, or Not active when your portal no longer includes image checks. Then turn them off in the camera's settings.

A view with very little detail, such as a blank wall, shows The view shows too little detail to check. Checking starts once it shows more.

Image alarms

Each confirmed fault raises one alarm named Image problem, with High severity, without any rule and whether or not the site is armed. Its message says what was found:

MessageFault
Image dark: the lens may be coveredCovered or dark
View blocked: the lens may be coveredCovered
Image washed out: the camera may be blindedBlinded
Camera moved: its view has shiftedMoved
View changed: the camera may have been turned or obstructedMoved or view changed
Image blurred: the lens may be dirty or out of focusOut of focus

Where your portal includes video evidence, the alarm carries a snapshot and a short clip of what the camera saw. It stays open after the picture recovers, so resolve it once you have checked the camera. Image alarms are handled like any other alarm; see Alarms and incidents. They are never sent to an alarm receiving centre.

After you move a camera on purpose

Resolve its Camera moved or View changed alarm while the camera shows the new view. The new view then becomes the normal one. If the camera is moved back instead, the problem clears by itself, but the alarm still waits for you to resolve it.