Sites
Create a Site for each physical location, open its workspace, put cameras in it, choose the evidence cameras for each alarm source and test a panel zone, set up API portals, and retire a Site you no longer use.
Contents
A Site is a physical location, such as a building or warehouse. Cameras, I/O devices, alarm panels and email inputs belong to a Site, and the Site's setup decides which cameras give evidence for its alarms. A role limited to some Sites grants its permissions only there.
Add a site
- Open Sites and select Add Site.
- Enter the Name, and optionally the Address and a Description.
- Select Add Site.
A new Site starts with an armed Whole site arming group; see Cloud arming and site controls.
Your package limits the number of Sites, retired ones excluded: see Settings > Portal profile > Portal limits.
To change its details, select Edit details under Site details in its workspace, then Save details.
Open a site's workspace
The Sites list shows each Site's cameras, address and Cloud arming state.
Select a Site's name, or Open workspace in its row. The header links to Monitor, Investigate and Alarms, filtered to this Site:
| Section | What it holds |
|---|---|
| Overview | Arming groups with Arm and Disarm, Offline equipment, Needs attention, enabled cameras, recent alarms, Site details and Setup summary. |
| Equipment | I/O devices, Panels and Email inputs. See Camera email alarms. |
| Arming | Cloud arming groups and schedules. See Cloud arming and site controls. |
| Camera associations | Cameras, Alarm evidence and Integrations (API), described below. |
| Floor plans | Plan images and device locations: Floor plans. |
| Response | Contacts and the assigned Response procedure, where enabled. |
| Alarm dispatch | Alarm receiving centres and their Site account numbers. See Send alarms to an alarm receiving centre. |
Equipment, evidence options and Alarm dispatch depend on your package.
Put cameras in a site
You choose the Site when you add a camera, and an enabled camera needs one. See Connect cameras.
To move a camera, an administrator opens it under Cameras, selects the Site name beside its name (Change Site, or Assign Site without one) and chooses the new Site in the Camera Site dialog. If roles on chosen cameras hold it, confirm with Move it.
Remove from Site, in the same dialog, takes the camera out of its Site and back to commissioning. Disable an enabled camera first. A retired camera keeps its Site.
Choose evidence cameras
When an alarm source triggers, Cloud attaches video from the cameras associated with it. A camera is always included in the evidence of its own alarms.
- Open the Site's Camera associations section and select Alarm evidence.
- Select an alarm source. Panel zones are grouped by panel and area, with Only zones without cameras.
- Choose the cameras that should give evidence for it.
- Select Save.
| Alarm source | Evidence cameras |
|---|---|
| A panel zone | Up to 4 |
| A camera alarm | The camera itself plus up to 3 more |
| An email input | Up to 4, including its source camera when present |
Evidence cameras can be at any Site, but not disabled or without video reaching Cloud.
Evidence never delays the alarm; for clip lengths, see Alarms and incidents. With AI verification, a panel zone or email input can have its own AI check below its cameras; see AI check.
With Operate Site outputs and See Sites at the Site, Test alarm on a panel zone tests its saved cameras: Run creates a [TEST] alarm with their clips and sends nothing out, unless you tick Also send it to the ARC as a test signal, where offered.
Integrations (API)
Where your package includes it, Integrations (API) lets another system, such as monitoring software, request a video link to a fixed set of cameras.
- Under Camera associations > Integrations (API), select New integration.
- Enter a Name and choose the cameras.
- Select Create integration.
- Copy and store the credential safely: it is shown only once.
Open an endpoint to Rotate credential or Revoke credential. Ask Kalytera for the request details your integrator needs.
Watch cameras in other applications
Where your package includes RTSP access, applications such as VLC can read a Site's cameras over RTSP. Under Edit details, set RTSP access to On, Digest sign-in, or On, Basic sign-in (RTSPS) where offered. People sign in with their Cloud email and password and see the cameras their live view shows; a camera's Connection tab has its addresses. Before using Digest, a person whose My account asks selects Confirm your password to use RTSP once.
Retire a site
A never-used Site can be deleted. One with history is retired instead, and its recordings, alarms and audit history keep their retention. First clear everything that still uses it:
- move or retire its cameras;
- move its panels to another Site;
- disable or move its email inputs;
- retire its Cloud arming groups and its I/O devices;
- remove its alarm receiving centres under Alarm dispatch, and any Site mapping under Settings > Receiver integrations;
- wait for any output or panel command that is still on its way.
- On the Site's Overview, at the end of Site details, select Retire or delete Site….
- Enter a Reason.
- Select Retire Site, or Delete Site for a never-used Site.
Retirement is terminal: the Site moves to Retired Sites and stays readable in history and search, but takes no new cameras or assignments.